How is the free air delivery worked out from a fill test?
FAD = V x (p2 - p1) / (p0 x t): the receiver volume times the pressure rise, over the atmospheric pressure times the fill time. A 500 l receiver filled from 7 to 30 bar(g) in 18 min: 0.5 m3 x 23 bar / (1.01325 bar x 18 min) = 0.6305 m3/min, that is 37.83 m3/h, 630.5 l/min or 22.27 cfm. The free air taken in, 0.5 x 23 / 1.01325 = 11.35 m3, is the air at the inlet conditions that the compressor delivered during the test; divided by the time it gives the average delivery over the pressure range.
Should I enter gauge or absolute pressures?
Either. Between two gauge pressures p2 - p1 is the same as between the matching absolute pressures, since both carry the same atmospheric pressure: 30 bar(g) - 7 bar(g) = 31.01325 bar(a) - 8.01325 bar(a) = 23 bar. A pressure without a mark is read as gauge, as the receiver gauge shows it; write bar(a), psia or a for an absolute pressure. When one pressure is gauge and the other absolute, the gauge one is made absolute by adding the atmospheric pressure, and the working says so.
Which atmospheric pressure goes into the formula?
The atmospheric pressure at the compressor inlet, p0, since the free air delivery is referred to the inlet conditions, as ISO 1217 defines it. Unless you enter it, the calculator takes the standard atmosphere, 1.01325 bar(a), as the air receiver calculator does, and labels it as an assumption. Where the barometer reads differently, or the compressor data state the rated FAD at another inlet pressure, enter that pressure (atm 1 bar). Deliveries in Nm3/h or SCFM refer to fixed reference conditions and are not taken.
What result is good enough against the rated FAD?
The calculator sets no acceptance limit. It gives the delivery from the test as a per cent of the rated FAD entered, and the time the fill would take at the rated FAD, so the two can be set side by side. Whether a result is acceptable follows from the compressor maker’s test procedure and the class requirement, which always come first.
Is the temperature taken into account?
No. The arithmetic is isothermal, which is an assumption: the air in the receiver is taken at the compressor intake temperature, and no temperature correction is applied. A temperature written in the line is left out, and the result says so. The result is the average delivery over the pressure range of the test, from the start to the end pressure.
Which units does the calculator take?
Volumes in l or m3, with a count of receivers filled together (2 x 750 l). Pressures in bar, mbar, kPa, MPa, psi (1 psi = 6.894757293168 kPa) or kgf/cm2 (98.0665 kPa exactly), each gauge or absolute. The fill time in h, min or s, also together (6 min 30 s). The rated FAD in m3/h, m3/min, l/min, l/s or cfm (1 cfm = 0.028316846592 m3/min, 1.699 m3/h). The atmospheric pressure in bar(a).