How is the condensate in the charge air worked out?
In four steps. The water in the intake air: pv = RH x ps(t1) and x1 = 0.622 pv / (pa - pv). The charge air pressure made absolute: p2 = gauge + pa. The most water the air can hold after the cooler: x2 = 0.622 ps(t2) / (p2 - ps(t2)). The condensate is x1 - x2 when that is above zero. Intake air at 35 °C and 70 % RH: ps = 0.05629 bar, pv = 0.03940 bar, x1 = 25.17 g/kg at 1.013 bar(a). Charge air 3 bar(g), 4.013 bar(a), 45 °C after the cooler: ps = 0.09594 bar, x2 = 15.24 g/kg. About 9.94 g of water condenses per kg of dry air; at 50 000 kg/h of air, 48 772 kg/h of it dry, that is 485 kg/h, or 11.6 t per 24 h.
Why does water condense when the air after the cooler is warmer than the intake air?
Because the air is compressed. The humidity ratio x1 does not change in the compressor, but the partial pressure of the water vapour rises with the total pressure: pv2 = x1 p2 / (0.622 + x1). The dew point rises with it. Intake air at 35 °C and 70 % RH has its dew point at about 28.7 °C at 1.013 bar(a), but at 4.013 bar(a) the same air has its dew point at about 54.8 °C, so a cooler outlet at 45 °C is about 9.8 K below the dew point and water condenses.
How is the dew point at the charge air pressure found?
From the vapour pressure of the charge air, pv2 = x1 p2 / (0.622 + x1), the inverse of the humidity ratio relation. The dew point td is the temperature at which the saturation pressure ps(td) equals pv2. The calculator finds it by bisection between 0 and 100 °C on the IAPWS-IF97 saturation-pressure equation, and shows the margin of the air after the cooler over it: above the dew point nothing condenses, below it the condensate is x1 - x2.
Where does the condensed water go?
It is removed by the water mist catcher and the drain after the cooler: the separator takes the droplets out of the air, and the drain takes the water away. The calculator gives how much water there is to remove, in g per kg of dry air and, with the air flow, in kg/h and t per 24 h. The amount depends on the humidity and the temperature of the intake air, on the charge air pressure and on the air temperature after the cooler.
What temperature should the air after the cooler have?
The calculator gives no recommended temperature: follow the engine maker’s guidance for the air cooler outlet temperature. What it gives is the water that condenses at the temperature entered, the dew point at the charge air pressure and how far the air after the cooler is above or below it, so the figures can be compared with the maker data.
Which inputs, units and range does the calculator take?
The intake air temperature in °C (K and °F are read too) with the relative humidity in %, or a humidity ratio in g/kg or kg/kg; the charge air pressure in bar, mbar, kPa, MPa, psi or kgf/cm2, gauge or absolute, read as gauge when it has no mark; the ambient pressure, 1.013 bar(a) unless entered; the air temperature after the cooler; and the air flow in kg/h, kg/s or t/h if wanted. Temperatures from 0 to 100 °C: below 0 °C the saturation is over ice, which the calculator does not cover.