| OMD-24 | OMD-24 · 15 ppm bilge alarm | Deckma | Two separate items: a computer unit that shows the reading and gives the alarm, and a measuring cell fed with water from the separator outlet. Each has its own label and serial, and the cell can be ordered on its own. As MEPC.107(49) requires, the alarm also records the operating status of the separator, so a gap in the log can sit on the separator side. |
| OMD-2008 | OMD-2008 · 15 ppm bilge alarm | Deckma | A computer unit with a measuring cell, like the OMD-24. Letters after the number on the label are part of the type and are copied with it, together with the serial of the computer unit and the number of the cell. The label, not the age of the ship, decides what is fitted. |
| OMD-2005 | OMD-2005 · 15 ppm bilge alarm | Deckma | A Deckma type with three items on the request side: a computer unit with a memory card for the data log, a measuring cell and a valve assembly. Each is identified from its own label before a line is opened. |
| OWSAN-0.5 · OWSAN-1 · OWSAN-2.5 · OWSAN-5 · OWSAN-7.5 · OWSAN-10 | OWSAN · two-stage separator | Detegasa | The two-stage bilge separator in Detegasa's current brochure: a coalescent filter in the first stage separates free oil by gravity, and an adsorption filter in the second stage breaks emulsions, with a suction-type pump feeding the unit. Adsorption cartridges, the coalescent filter element, suction pump wear parts and monitor items are the recurring lines; the figure after OWSAN is the size and belongs in the request. |
| OWSAN-P | OWSAN · integrated monitor | Detegasa | The newer OWSAN model, whose control panel integrates the oil monitor and the operator interface. On a -P unit the monitor items are quoted against the panel rather than as a separate bilge alarm, alongside the same cartridge and filter lines as the OWSAN. |
| DELTA OWSA | DELTA · two-stage, adsorption | Detegasa | A DELTA-type two-stage design built to IMO MEPC.107(49): a gravity static separator followed by an adsorption stage. Adsorption cartridges, pneumatic valve items for oil discharge, overboard, recirculation and adsorption bypass, the flushing solenoid valve and the 15 ppm bilge alarm monitor parts are the recurring lines. |
| DELTA OWS | DELTA · single separator | Detegasa | The older separator built to IMO MEPC.60(33), with a tank and internals, a pump, pneumatic valves and electrode-controlled oil discharge. The oil content monitor was an option on this build, so confirm whether one is fitted before monitor parts are listed. |
| STPN · DELTA STPN | STPN · biological sewage plant | Detegasa | Aerobic biological sewage plant for black and grey water, offered in modular or containerised versions and suited to vacuum or gravity collection. Air blower items, the effluent discharge pump, dosing equipment where chemical disinfection is fitted, and level and control items are the usual lines; send the plant figure from the plate as written. |
| PRBN · DELTA PRBN | PRBN · biological sewage plant | Detegasa | Biological plant for black water only, built for a reduced footprint. Blower and discharge pump items are the recurring lines, with dosing items where fitted; state PRBN rather than STPN, since the two treat different waste streams. |
| MBR | MBR · membrane bioreactor | Detegasa | Membrane bioreactor plant for large crews: collecting, aerobic and membrane tanks, with submerged membranes that Detegasa names as Mitsubishi Rayon and automatic backflushing, and no chemicals needed for disinfection. Membrane modules, the recirculation pump and aeration items are the recurring lines. |
| IRA | IRA · solid waste only | Detegasa | Marine incinerator designed to burn solid waste only. Diesel-oil burner items, exhaust gas fan and damper items, exhaust-gas thermocouples, refractory blocks and door and sluice seals are the recurring lines; the size follows the letters, as in IRA-10. |
| IRLA | IRLA · solids and sludge | Detegasa | Incinerator designed to burn solid waste and sludge, simultaneously where required. Next to the burner, fan, damper and refractory items it may carry Detegasa's optional sludge tank, whose heating, sludge circulation pump, level switches and safety valves form their own group of lines. Sizes are written as in IRLA-50. |
| DELTA IR-10 | DELTA · solid-waste incinerator | Detegasa | A DELTA solid-waste incinerator type from an older Detegasa specification: incinerator, diesel-oil burner and control panel on a baseplate, with the exhaust gas fan, regulating damper and exhaust-gas thermocouple supplied loose. The specification lists those loose items separately, so name them as separate lines. |
| OILCHIEF | DVZ-FSU OILCHIEF | DVZ | The OILCHIEF plants are bilge water treatment units rather than centrifuges, and the items that are renewed are the coalescer and filter inserts, the oil content monitor parts, level probes and solenoid valves. Quote the unit type and serial, and send the type approval certificate held aboard with the request. |
| Oilmaster · DVZ 1000 VC | Oilmaster | DVZ | The Oilmaster designation appears with a figure and a letter group after it, and the letters carry the execution. Inserts, monitor cell and lamp items, gaskets and the automatic valve set are the recurring lines; the insert and the monitor are what an inspection looks at first. |
| 3SEP | 3SEP · two-stage | JOWA | The 3SEP is a two-stage bilge water separator working on differential specific gravity, coalescence plates and filtration, and it was offered in several sizes under one designation. State the size from the unit plate, because the insert and plate pack follow it rather than the family name. |
| Seaguard | Bilge alarm / oil content monitor | JOWA | Seaguard is JOWA's bilge alarm and oil content monitor, sold both as part of a 3SEP installation and as a standalone retrofit. The measuring cell, sample line, seals and the alarm or display unit are the parts that wear; state whether the monitor is factory-fitted or retrofitted, since the mounting kit differs between them. |
| SMART BILGE | SMART BILGE · 15 ppm bilge alarm | Rivertrace | The Rivertrace bilge alarm type built for MEPC.107(49). Copy the type exactly as the rating label prints it, with any sign or letter after the name, and add the serial and the supply voltage. Any part for it, from the cell to a board, is matched to all three, not to the name alone. |
| SMART CELL | SMART CELL · cell or whole monitor | Rivertrace | The name is met in two places. Rivertrace material uses it for the measuring cell of the SMART BILGE, while trader listings use Smart Cell or Smart Cell Bilge for a whole monitor. Say which item carries the name on your ship, the cell or the monitor housing, and photograph that label; the two lead to different lines. |
| OCD CM | OCD CM · earlier bilge monitor | Rivertrace | An earlier Rivertrace monitor, built to MEPC.60(33), the resolution that MEPC.107(49) later superseded. OCD CM units are still met behind separators. A part for an OCD CM is never assumed to fit a SMART BILGE, or the other way round; each type is quoted from its own label. |
| SKIT/S-DEB · SKIT/S-DEB-SPS | SKIT · suction type | RWO | The SKIT/S-DEB is the suction-type separator combining a coalescer with an emulsion-breaking absorber, and the type is out of production while units remain in service. The absorber and coalescer inserts, gaskets, level probes and the automatic discharge valve are the recurring lines, and the slash in the designation belongs in the request as written. |
| OWS-COM | Oil content monitors | RWO | The monitor is a separate item from the separator and fails separately, so it is worth naming on its own line. Measuring cell, lamp or light source, seals and the sample line items are what is renewed, and the certificate reference identifies which monitor build the plant was approved with. |
| CBM+ | Continuous bilge monitor | RWO | CBM+ is RWO's newer continuous bilge monitor, logging discharge data against GPS position rather than only reading oil content at the point of discharge. It sits alongside OWS-COM rather than replacing it on every installation, so confirm which monitor is actually fitted before quoting. Measuring cell, sample-line fittings, seals and the display or logger unit are the recurring lines. |
| PURELIO | Two-stage separator, current line | Sasakura | PURELIO is Sasakura's current oily water separator, a two-stage unit with a second-stage coalescer designed to come out for servicing without pulling the plant off the vessel. Coalescer cartridges, filter inserts, gaskets and the monitor's measuring cell are the recurring lines. Confirm which generation is fitted — an older installation may still carry the generic bilge-separator nameplate rather than the PURELIO name. |
| US series 15 ppm bilge separator | Taiko separator line · US series | Taiko Kikai | Coalescer-type 15 ppm bilge separator: gravity stage, coalescing stage, oil-collecting space, level sensing and an automatic oil drain to the sludge tank. Rated throughput is read from the plate, because element sizing and cartridge count follow it. The series designation on the fitted unit is taken from the plate photograph rather than from the spares list. |
| USH series 15 ppm bilge separator | Taiko separator line · USH series | Taiko Kikai | The same 15 ppm bilge discharge task under a second Taiko series designation. What the suffix encodes is confirmed against the maker's own literature for the fitted unit rather than inferred here, and rated throughput is again read from the plate because element sizing and cartridge count follow it. |
| OG120C | OG series | TeamTec | OG120C is the first size in TeamTec's OG range. Its burner, sludge dosage and combustion chamber items carry their own item numbers, so a part is never carried over from an OG200 or OG400 list on the strength of a similar name. The type and serial from the plate open the right list. |
| OG200C · OG200CS · OG200CW | OG series · versions | TeamTec | The OG200 appears with several version suffixes, both in the maker's range and in parts listings elsewhere. The suffix belongs to the type and changes what is fitted on the unit, so each line is quoted against the full designation on the plate, never against the size number alone. |
| OG400C · OG400CS · OG400CW · OG400CSW | OG series · versions | TeamTec | The OG400 shares its set of version suffixes with the OG200, so the same care applies to the letters. Its sludge dosage pump is a progressive cavity pump, and the stator, rotor, joints and pump seal are wear lines quoted against an OG400C next to burner and door items. |
| GS500C · GS500CS · GS500CSW | GS series · versions | TeamTec | The GS500 is listed in more versions than any other GS model, so the suffix carries real weight here. Burner, sludge dosage, combustion chamber and flue gas fan items follow the same four assemblies as on the OG units, but with their own item numbers and sizes. |
| GS900CX | GS series | TeamTec | GS900CX is the GS900 designation that the maker and independent parts listings spell the same way; other GS900 suffixes are written differently from one source to the next, so the plate decides. Sludge burner, dosage pump and refractory lines are read against the serial. |