Terasaki Circuit
Breaker Spare Parts
TemPower 2 AR air breakers · TemBreak moulded case · AGR trip units
Terasaki families a switchboard request can reference
Terasaki Electric Co., Ltd. of Osaka builds circuit breakers and it builds the marine switchboards they sit in, and it continues to trade under its own name. That double role is why a request from a ship arrives sometimes as a breaker type, sometimes as a panel designation and often as both. The company name itself identifies nothing: the Japanese legal name carries an extra word that the English trading name drops, earlier company names appear on older equipment, and European and Australian literature circulates under regional entities, so the name printed above a designation does not tell you which factory built the unit.
Air circuit breakers, and where the type stops
Every TemPower 2 designation begins AR and ends in the breaking capacity class, which the maker's order form gives as S, H or SB. The three digits between are not a bare ampere figure: the maker lists AR216H and AR316H as separate breakers that share an ampere frame, so the first digit is copied as carefully as the other two, and the whole type is read from the plate on the breaker rather than from a table. The maker's own order form then asks for three things the type does not contain: the rated current actually fitted, the sensor kit rating where it differs from it, and the pole count. The overcurrent release is a further designation again, ordered separately from the breaker. A newer TemPower PRO line sits beside TemPower 2 on the manufacturer's current breaker index.
The first moulded case generation
Types in the original TemBreak range begin with an X, and the letter after it names the series — economical, standard or high fault. These plates are still in service, and the catalogue that replaced them says of them plainly that their frame sizes vary from TemBreak 2. So the generation has to be settled before the frame number means anything: a part that fits an XS250 does not follow from a part that fits an S250, however alike the two strings look on a requisition.
Model, frame and a two-letter type
TemBreak 2 drops the X on most frames and writes the designation as a model letter, the ampere frame, then a two-letter type: the maker's own data sheets split S250-NJ into model S250 and type NJ. The largest frames revert to an XS prefix, which is one reason a prefix should never be decoded from memory. The second letter of the type is what says whether the breaker is thermal-magnetic or electronic, and it is the field most often lost when a designation is copied by hand.
The range that renewed TemBreak 2
The manufacturer states that the TemBreak 2 moulded case series has been renewed as the TemBreak PRO series, and gives the line as covering moulded case circuit breakers across several frame sizes. Its breaker index adds that TemBreak PRO has so far been launched for Asia and Australia only, with other regions to be announced, and asks buyers to consider the conventional TemBreak 2 in the meantime, so outside those regions TemBreak 2 is still the line the maker points to. It publishes no changeover year, so a PRO plate is treated as its own identification rather than as a dated successor to a TemBreak 2 part number. Send the string as it reads and let the generation follow from it.
Earth leakage and residual current protection
The manufacturer's breaker index carries moulded case breakers with an earth leakage function alongside a separate TZS series of earth leakage relays, and the TemBreak 2 range includes breakers with integral residual current protection catalogued on their own as CBRs. A device of this kind has a residual current setting as well as an overcurrent rating, so a line naming only the frame and the current has sent half the identity. State the residual current setting and whether it is fixed or adjustable.
HS21, HS50, MS22, APS22 and the group starters
Terasaki also builds the boards: HS21 and HS50 medium-voltage switchgear, MS22 low-voltage power distribution, APS22 arc-proof switchgear and controlgear, the GS22 and GS50 group starter panels, and the TERANET50X control and monitoring system alongside them. HS21 is metal-clad to IEC 62271-200, each section divided by metal partitions into four compartments — circuit breaker, main busbar, cable terminations and low voltage equipment. Where the panel is a Terasaki board, the switchboard drawings and the discrimination study are Terasaki documents and are usually still on board.
A Terasaki type is a set of fields, not one code
In the first TemBreak range the type opens with an X and the letter after it is the series: XE is the economical series, XS the standard series and XH the high fault series. The number that follows is the ampere frame. The letter on the end is the trip: S a fixed thermal trip, J an adjustable thermal trip, E an electronic trip, and D a special DC application. Three fields, and only the middle one is a number, which is why a request quoting the number alone leaves out both the series and the trip.
TemBreak 2 keeps the same idea and moves the letters about. The catalogue number is built as a model letter, the frame rating in amperes, and a two-letter type. The model letter separates the economical, standard, high, limiting and earth leakage classes; the first letter of the type is the breaking capacity class; and the second letter is the protection actually fitted — F fixed thermal and fixed magnetic, J adjustable thermal and adjustable magnetic, E electronic, and N no protection at all, which makes the device a switch-disconnector rather than a breaker. That second letter carries the whole thermal-magnetic against electronic question, it decides whether a current sensor and a control supply sit behind the device, and it is printed on the plate.
Neither string is the full ordering description. After the type come an optional-function code, the pole count, the rated current fitted and the connection type — front connection, extension bar, cable clamp, rear connection, plug-in or DIN rail mounting — and on the air circuit breakers the overcurrent relay is written out separately again. Read the whole string off the equipment rather than decoding a prefix from memory. The letters have not been used consistently between generations or between regional catalogues: a Z prefix means one thing in the European TemBreak 2 range and something else in the Australian one, and a page like this cannot publish a key that survives both.
What is actually ordered off a Terasaki breaker
The list runs in the order a switchboard is worked: the arc path first, then the trip and closing devices behind it, then the auxiliary and control items, then the draw-out cradle the body sits in, then the moulded case feeders in the same board. Routine consumables and survey items are marked, because on this equipment that distinction decides whether a line is a stores order or a conversation with a surveyor.
- Arc chambers, two per pole on an air circuit breaker — routine consumable once cleaning no longer clears the deposits
- Moving and stationary main contacts, quoted as a matched pair rather than singly — routine consumable, replaced together when one tip is damaged or worn past the manual's limit
- Arcing contacts and their mounting hardware — a survey item where classification society rules apply, because the mounting nut is a named inspection check
- AGR overcurrent relays — AGR-11B, AGR-21B, AGR-22B and AGR-31B — a survey item, since the settings belong to the panel and not to the breaker
- Power current transformers feeding the overcurrent relay in the main circuit
- Latch release coils
- Magnet hold triggers
- Shunt trip devices, continuously and instantaneously rated, and the AQR-1 capacitor trip device fitted alongside them
- Undervoltage trip devices with their control device, AUR-1CS for instantaneous or AUR-1CD for delayed tripping — consumable when coil resistance or plunger stroke falls outside range
- Closing coils, spring charging motors and the manual charging mechanism kept for inspection
- Control relays
- AXR auxiliary switches in four, seven and ten change-over contact versions, normal or gold-contact microload — routine consumable when the contacts roughen
- Position switches for the INSERT, ISOLATED, TEST and CONNECTED positions
- Non-auto trip indication switches, spring charge switches, ready-to-close switches and ON-OFF cycle counters
- Draw-out cradles, complete or as a body-only replacement into the cradle already in the panel
- Main circuit and control circuit safety shutters, which belong to the cradle and not to the body
- Breaker fixing bolts, including the red bolt standard on machines built to classification society rules — survey item
- Shutter opening trucks and test jumpers
- Door interlocks, horizontal and vertical mechanical interlocks between breakers, cylinder locks, padlock facilities and Castell fittings
- Complete moulded case breakers, which is what the maker's own inspection table calls for on worn contacts, a cracked case or a failed insulation test — a survey item after any fault interruption
- AX auxiliary switches and AL alarm switches, field-installable, the first indicating ON or OFF and the second indicating TRIP
- Shunt trips and undervoltage trips for moulded case breakers
- Motor operators and handles, whose own designations carry the generation: T2MC motor operators and T2HB or T2HP handles belong to TemBreak 2, TPMC, TPHB and TPHP to TemBreak PRO
- Terminal covers, phase barriers and insulation accessories — the terminal cover is part of the device envelope rather than an option
What Terasaki's own service form asks for
The TemPower 2 instruction manual prints the maker's request form, Table 41, headed "Information you are requested to state". It asks for the type and serial number off the rating nameplate, the main circuit rated current and rated voltage, the spring charging method, the overcurrent release type, and then the rated operation voltage of the electrical tripping device, the shunt trip and the undervoltage trip separately — the accessory control voltages, not only the breaker type. The list below is built around that form, because a quotation needs the identical set of data and for the identical reason.
- Breaker type exactly as printed on the rating nameplate — the full string with every letter, not the frame number alone
- Serial number from the rating nameplate, the pole count, and any special specification numbers marked SR, SS or SO, which the maker's request form asks for on a line of their own
- Rated current actually fitted, which is a separate figure from the frame written into the type
- Overcurrent relay or trip unit designation copied in full from its own label, closing letter included: on TemPower 2, AGR-21BL, AGR-21BR and AGR-21BS are the general feeder, IEC 60255-3 and generator protection versions of one relay
- Whether the trip unit is thermal-magnetic or electronic, and whether it reads out on a dial or a display
- Present trip unit settings photographed from the dials or the setting screens, with the protection coordination study or setting schedule from the switchboard file where it is on board
- Fixed or draw-out construction, and whether the cradle stays in the panel or forms part of the request
- Terminal arrangement at the top and at the bottom stated separately — vertical, horizontal, front connection, rear connection or plug-in base
- Whether the cables land on lugs at the front, on busbar at the rear or through a plug-in base, photographed with the door open
- Auxiliary and alarm switches fitted, with their contact count, and whether the unit was built to classification society rules
- Shunt trip, undervoltage release and closing coil, each with the control voltage marked on its own label
- Spring charging method — hand lever or motor — and any motor operator on a moulded case breaker
- Duty of the circuit: generator incomer, bus tie, main feeder or motor circuit, and for a generator breaker the generator's full load current
- Rating nameplate, specification nameplate and trip unit label photographed square-on, and the breaker photographed in place with the panel door open
- Operating history where it is known: the reading from the cycle counter, and whether the breaker has interrupted a fault
Tools for this equipment: the marine cable designation reader and the wire size converter for the cables that land on its terminals. Where the protection on a generator or feeder breaker is shown on the single-line drawing by ANSI device numbers, the protection device number reader decodes them.
Where a shipboard unit parts company with its industrial namesake
The clearest example is a switch nobody looks at. On a draw-out air circuit breaker the standard auxiliary switch operates in the CONNECTED and TEST positions; on an ACB conforming to classification society rules it operates in the CONNECTED position only. The order form states it from the other direction as well: select a mechanical interlock and a marine type auxiliary switch is what gets supplied with it. The second difference can at least be seen — the red breaker fixing bolt, which locks the body in the CONNECTED position even under strong vibration, is standard equipment on ACBs that conform to ship classification society rules, and the inspection procedure adds a check of the moving arcing contact mounting nut for looseness where those rules apply. None of these differences alters the type designation on the front of the machine, which is why they have to be stated in a request rather than looked up from it.
The maintenance schedule makes the same point about wear. The TemPower 2 manual sorts the working environment into standard and harsh: its standard column names an engine room with air conditioning, and its harsh column an engine room without air conditioning, together with heavy dust, corrosive gases, high ambient temperature and humidity, and constant exposure to vibration. In that category the inspection interval falls to every year, and to every six months once the installation is two years old, against every one or two years in normal service. The moulded case manual shortens its own intervals again for atmospheres carrying sulphurous acid, hydrogen sulphide or salt, and the air circuit breaker order form offers tropicalisation, anti-corrosion and cold climate treatment as options taken at order time. A treated breaker and an untreated one share a type designation, so the treatment is one more thing the plate will not tell you and the switchboard file will.
Two families, two shapes of enquiry
On the air circuit breakers Terasaki publishes field replacement procedures for the arc chambers, the stationary and moving contacts, the latch release coil, the shunt trip device, the control relay, the magnet hold trigger and the auxiliary switches, and its inspection table gives the criteria that generate those orders: polish discoloured or roughened tips, renew both contacts when one is damaged or has worn past the limit, replace an arc chamber that will not clean up, replace an undervoltage trip whose coil resistance or plunger stroke is out of range. An ACB enquiry is therefore component-level, and it usually arrives as a list rather than as a line. The manual also draws two boundaries the enquiry has to respect: thorough inspection and overhaul are reserved to the manufacturer's own works, and a breaker that has performed three tripping operations near its rated breaking current is at the end of its safe service life and should be replaced rather than worked on again.
The moulded case side runs the other way. In the maker's own periodic inspection table the remedy for worn contacts, a cracked cover or base, a stiff handle, terminals discoloured by overheating and an insulation resistance below the stated limit is, in every case, replace; and after a short circuit, a breaker whose operating handle and arc gas vents are heavily contaminated with soot and molten metal particles is to be replaced without delay. An MCCB enquiry is consequently the device plus its accessories — the field-installable auxiliary and alarm switches, shunt trips, undervoltage trips, motor operators, handles, terminal covers and insulation parts. That split also decides where a verified alternative is worth reviewing: hardware, terminal covers, insulation parts and interlock fittings are ordinary supply questions, while the breaker itself, the trip unit and anything inside a class-surveyed panel stay on the OEM route, because a type approval certificate names type designations and states on its face that a significant change in design or construction may render it invalid. Type approval does not certify the equipment as installed either, so where a replacement has to satisfy a surveyor, the approval status for the specific breaker is confirmed against the certificates held with the vessel's own documentation before the line is ordered.
What buyers ask before sending a Terasaki list
What information is needed to quote Terasaki circuit breaker parts?
The breaker type and serial number exactly as printed on the rating nameplate, the pole count, the rated current actually fitted, and the overcurrent relay designation copied from its own label. Whether the breaker is fixed or draw-out matters as much as the type, because the draw-out cradle carries the safety shutters, the position switches and the door interlock, and a body ordered alone will not bring any of them. Photographs of both nameplates, of the trip unit and of the terminals with the panel door open usually settle the rest. Vessel and IMO number, the port and the ETA help route the request.
How is a Terasaki breaker designation read?
As fields, not as one code. On a moulded case breaker the first letter is the model class, the number is the ampere frame, and the two letters after it give the breaking capacity class and the protection fitted, where F and J are thermal-magnetic and E is electronic. On an air circuit breaker the type begins AR and ends in the breaking capacity class, S, H or SB; the three digits between are copied whole, because AR216H and AR316H share an ampere frame and are still different breakers; and the rated current and the relay are written out separately again. Copy the whole string from the equipment rather than decoding a prefix from memory: the letters have been used differently between generations and between regional catalogues, and frame numbers do not carry across from the first TemBreak range to TemBreak 2.
Can a Terasaki trip unit be quoted from the breaker type alone?
No, and this is where most enquiries stall. The overcurrent relay has its own designation, ending in a characteristic letter — L for general feeder circuits, R for characteristics to IEC 60255-3, S for generator protection — and function letters for ground fault, pre-trip alarm or reverse power, several of which are mutually exclusive and were chosen when the switchboard was ordered. A relay for a generator breaker also needs the generator's full load current before it can be specified at all. The settings are a further layer again: they come from the discrimination study held with the switchboard documentation, not from the breaker, so a replacement relay arrives at default values until somebody sets it to that panel.
What is usually ordered when a Terasaki breaker is opened up?
It depends which family it is. On the air circuit breakers the maker publishes field replacement procedures for the arc chambers, the moving and stationary contacts, the latch release coil, the shunt trip device, the control relay, the magnet hold trigger and the auxiliary switches, and the contacts are renewed as a matched pair rather than singly. On the moulded case breakers the maker's own inspection table answers worn contacts, a cracked case and a failed insulation test with one word, replace, so what is ordered there is the complete device plus the field-installable accessories. An engine room without air conditioning counts as harsh service in Terasaki's own maintenance table, which is why these items come round sooner at sea than they would on the same breaker ashore.
A Terasaki breaker has interrupted a short circuit. What should be ordered?
Settle the family first, because the answers are opposite. An air circuit breaker that has performed three tripping operations near its rated breaking current is, by the maker's manual, at the end of its safe service life; short of that limit it is repaired component by component. A moulded case breaker whose operating handle and arc gas vents are heavily contaminated with soot and molten metal particles is to be replaced without delay.
How does a switchboard request differ from a breaker request?
The switchboard has documentation of its own, and it is usually on board. Where Terasaki built the panel, its drawings and discrimination study are Terasaki documents too, and a reference to them settles the settings and the duty of the circuit faster than any photograph.
Is Vessel Core connected to Terasaki?
No. Vessel Core is independent of Terasaki Electric Co., Ltd. Terasaki names, series names and type designations are used on this page only to help identify equipment already installed on board, so that a spare parts request can be structured and routed for quotation; naming this equipment implies no dealer, distributor or partner relationship, and no endorsement by the manufacturer. Where a replacement has to satisfy a surveyor, the approval status for the specific breaker is best confirmed against the certificates held with the vessel's own documentation before the line is ordered.
Why the maker name appears on this page
Submit your RFQ now.
Send your Terasaki request — state whether the breaker belongs to the TemPower 2 AR air circuit breaker range or the TemBreak moulded-case family, and whether a trip unit, contact set or switchboard spare is needed. A photograph of the breaker's own rating plate is what confirms it.